Discover SNOWVENTCO Storm Vents
Tested hurricane and blizzard proof
BUILDING CODE APPROVED
Miami Dade TAS 100 Approved (hurricanes)
Protect your home with a revolutionary roof vent
Discover SNOWVENTCO Storm Vents.
The ONLY Type B 50 sq. in. flow static box vent that actually keeps out over 99% of snow in blizzard conditions.
The SNOWVENTCO Storm Vent was created by a roofer to tackle tough Canadian winters. Approved by the Canadian Standards Association, SNOWVENTCO Storm Vents have been tested to stop over 99% of snow and effectively redirect rain during severe storms. Plus, these vents are tough enough to resist hail damage.
Many roof vents fail during severe storms, letting snow and rain get into the attic, leading to rot, mold, damaged insulation, leaks, and upset homeowners. Remediation is costly. Whether it's your house, garage, or garden shed, SNOWVENTCO roof vents are the ideal choice for ensuring a dry and well-ventilated space.
Designed and manufactured in Canada, SNOWVENTCO's patented, CSA-approved, polypropylene and stainless steel design allows heat and moisture to escape your attic… while providing a NO-CLOG, effective barrier to snow, rain, insects and vermin. And we've got the test to prove it!
Upgrade your attic ventilation system with SNOWVENTCO Storm Vents—a perfect blend of style, durability, and functionality. Our low-profile design circulates air while seamlessly blending with your roof line. Choose from EXHAUST or INTAKE versions to meet all your passive ventilation needs.
SNOWVENTCO Storm Vents
THE NEXT GENERATION IN ATTIC VENTILATION
MONEY BACK
GUARANTEE
WARRANTY
SHIPPING
in CANADA & USA*
How do SNOWVENTCO Storm Vents protect your attic from moisture?
Constructed with a heavy-duty ¼ inch thick polypropylene shell and 304 grade stainless steel filter, the SNOWVENTCO Storm Vent provides a no-clog, 99.99% impenetrable barrier to snow, rain, and other elements.
UNIQUE MICROPORE STAINLESS STEEL FILTER
The next generation in ventilation begins with SNOWVENTCO'S STAINLESS STEEL SMART FILTER. Thousands of 120-micron holes keep out driven rain and snow particles and other unwanted elements.
ENGINEERED NOT TO CLOG
Snow and dirt won't block the vent, thanks to the porcelain-like smoothness of the steel screen and the outflow of warm air from the attic, which continuously cleans the filter.
EXCEEDS CSA REQUIREMENTS
The SMART FILTER provides over 80 sq inches of open airspace for a 50 sq inch vent. This 60% over-engineering of net free area (NFA) ensures strong attic airflow while the filter completely blocks the elements.
Why do roofers prefer SNOWVENTCO Storm Vents?
Heavy-Duty Construction
Extra-thick polypropylene construction and the steel filter ensure the vent can handle a lot of punishment. The hail resistant SNOWVENTCO
Storm Vent withstands over 180kg/400lb of standing weight.
Oversized Flange
A wider flange makes installation a snap and helps improve the overall seal. This simple improvement has been demanded by roofers for years.
Arched Design
An arched collar and cap help snow slide off the vent, avoiding build-up behind the vent. The arched deflector on our intake vent diverts rain.
SNOWVENTCO Storm Vents
Upper Roof Exhaust Vent
Install near roof peak to allow warm air to escape. Blocks 99% of snow, diverts rain.
Lower Roof Intake Vent
Suitable for use in place of soffit vents. Blocks 99% of snow, effectively diverts rain.
Skylite Exhaust Vent
Perfect for sheds and garages to allow light in while keeping moisture out.
Who buys SNOWVENTCO Storm Vents?
Builders
As a builder, you understand the importance of preventing snow and rain from entering attics during severe storms, as well as the health and legal issues that can arise from mold growth.
Roofing Contractors
As a roofing contractor, you know how important it is to provide your customers with the best possible products and services. SNOWVENTCO Storm Vents are designed to keep snow out of attics.
Homeowners
During a storm, the last thing you want to worry about is moisture getting into your attic through roof vents. Moisture in attics destroys insulation, causes water damage, and leads to mold growth.
Frequently Asked Questions
Roof vents are necessary in order to improve the ventilation in your attic. Adequate ventilation helps to remove excess heat and moisture from your attic, which can prolong the life of your roof and prevent damage to your attic and the rest of your home. Additionally, proper ventilation can help to prevent the growth of mold and mildew, which can be a health hazard.
There is no one "best" roof ventilation system as the appropriate system will depend on the specific needs of your home and roof. Roof vents are generally divided into active or passive systems with each system having its pros and cons.
The number of roof vents you need will depend on the size and layout of your attic. A general rule of thumb is to have 1 square foot (144 square inches) of vent area for every 150 square feet of attic space. For example, if your attic is 900 square feet, you would need 864 square inches (6 square feet X 144) of vent area. Additionally, it's important to make sure that your vents are properly placed and balanced, with an equal amount of intake and exhaust vents. This will ensure that air is flowing effectively through your attic and not creating pressure that could cause leaks or damage to the roof. Try our roof vent calculator to find the right amount of vents for your roof.
Installing roof vents can be a complex task that requires a certain level of skill and experience. It is recommended that you hire a professional roofing contractor to install your vents, as they will have the knowledge and tools necessary to do the job safely and correctly. However, if you're determined to install them yourself, take a look at our installation video for a step by step demonstration.
No, determined vermin will have a difficult time chewing through the heavy duty plastic outer shell which is much thicker than typical roof vents. If they are able to chew through the plastic they will not be able to get through the stainless steel filter. This will restrict attic access through the vent openings.
Roof vents can breathe under snow, but it depends on the amount of snow and the type of vent. SNOWVENTCO Storm Vents have been tested to allow for airflow even under heavy snowfall conditions. See the link below for video proof.
Yes, the low profile and aerodynamic design of SNOWVENTCO vents combined with heavy duty polymer outer shell mean the SNOWVENTCO vents are very resistant to high winds. Our vents have undergone testing showing that they prevent over 99% of rain, snow, and other particle penetration of attic in CAT 3 hurricane wind conditions. They are also durable enough to stay intact when faced with 120 mph winds.
Keep Your Attic Dry
Buy SNOWVENTCO Storm Vents Online
MONEY BACK
GUARANTEE
WARRANTY
SHIPPING
in CANADA &
CONTINENTAL USA